Showing posts with label electroplating waste. Show all posts
Showing posts with label electroplating waste. Show all posts

Thursday, October 19, 2017

Polution Control of Chrome Plating

Environmental protection become very strict currently and chrome plating industry include of one Industries that can contribute to pollute environment. To lessen on polluting environment several tips on doing electroplating should be done:
  • Reduce Dragout and Water use: Minimized dragout and to minimize extent possible, return residual dragout to the process tank.
  • Install dragout racks over tanks or drip guards and return solution to process tank
  • Perform initial rinse tank with return of solution to process tank
  • Avoid solution disposal by minimizing bath contamination and using available maintenance technology recycle wwtp (waste water treatment plant)
  • Minimize Chromium fume to air emission to workplace and community. Use less toxic substitute technologies where applicable.
  • Use developed technology on process waste water for example ion exchange technology, ion transfer technology or membrane electrolysis.
This one is diagram of ion transfer technology that used in Navy testing.



ion transfer technology

Other Site:

Friday, August 30, 2013

Sulfuration Treatment or Selective Metal Recovery on Electroplating Industry

As state on the journal of electroplating that is released in Global Nest written by some experts from Japan, said the difficulties of separate of metal content on electroplating sludge makes it difficult to recycle and reuse them. In the viewpoint of environmental protection as well as resource saving, the effective methods for recycling and reuse of sludge metal are required to be developed urgently.

Selective recovery method of metals from mixed metal waste water by sulfuration treatment is proposed. Sulfuration treatment is characterized by low solubility of metal sulfides; metal sulfides are, in general, lower in solubility than that of metal hydroxides. Separation of metal like copper, zinc and nickel which are commonly use from mixed solution in various pH ranges was conducted by employing three sulfurating agents; sodium sulfide (Na2S), sodium disulfide (Na2S2) and sodium tetrasulfide (Na2S4). Aqueous solution of CuSO4, ZnSO4 and NiSO4 and those of real plating wastewater, of which the initial concentrations were adjusted to 100-300 mg dm3 were employed.

By sulfuration treatment of the solution using sulfurating agent without adjusting pH, CuS was first precipitated, but ZnS and NiS were also precipitated at the same time. The result saw from the formation behavior of metal prcipitates depended on pH value of the solution. For the sulfuration with three kinds of sulfurating agent, copper was first separated from the solution as CuS in pH = 1.4 – 1.5, then ZnS was separated in pH = 2.4 – 2.5, followed by the precipitation of nickel sulfide, NiS in the residual solution as pH = 5.5 – 6.0. The effective agent to make selective precipitation of sulfides use Na2S, Na2S2 and Na2S4. The selective of CuS in the filtrated cake obtained by the sulfuration treatment in pH = 1.4 – 1.5 was about 94%. The sequence selectivity of ZnS and NiS in the cake after the sulfuration treatment in pH = 2.4-2.5 were 75-77 % and about 20%, respectively. The selective of NiS and ZnS in the cake after sulfuration treatment in pH = 5.5 – 6.0 was 64% and 33 – 35 % respectively.


Waste Treatment:




Tuesday, February 12, 2013

Waste Water Process of Electroplating

Many kind of process has been done and propose to process waste water from electroplating industry. Waste water process discuss here is to process waste water from electroplating industry using absorption method using zeolite soil. Zeolite soil have characteristic can adsorb many materials like metal from the solution.

The sorption behavior of natural zeolite and synthetic zeolites has been studied with respect to Cr(III) on chromium plating, Ni(II) on nickel plating, Zn(II), Cu(II) and Cd(II) in order to consider its application to purify metal finishing waste water. On the batch method has been employed using metal concentrations in solution ranged from 10 to 200 mg/l and solid/liquid ratios ranged from 2.5 to 10 g/l. Synthetic zeolite exhibited about 10 times greater sorption capacities than natural zeolite, and most suitable to perform metal waste water purification processes. This mineral showed the same high sorption capacity values when used in the purification of metal electroplating waste waters.